Alarm Manuals

Bosch 6000

  • Arming the Panel

    1. Enter PIN, then press the [ON] key.
    If your PIN is valid and if all zones are normal, exit delay time will start. You should leave now. If your control panel detects a faulted zone, you should return it to normal, or bypass the zone.
    During exit delay, you may stop the area from turning on by entering your PIN followed by the [OFF] key.

  • Disarming the Panel

    1. Enter your PIN, then press the [OFF] key.
    Duress or silent alarms
    To trigger a duress, enter your normal user PIN followed by the last 2 digits of your PIN followed by the ON or OFF key. See the following examples.
    1. If your PIN is 2580, to send a duress report when the area is off, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON]
    2. If your PIN is 2580, to send a duress report when the area is on, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF]

  • Bypass Zones

    1. Enter [MENU] + 3 + 0 + 2
    2. A list of zones that can be bypassed will display on the keypad. A tick disaplyed on the right side of the zone name indicates that the zone is already bypassed. Use the up and down keys to select the zone that you want to bypass, then press [OK]. Alternatively, you can enter the zone number that you want to bypass then press [OK]
    3. Press [ON] or [OFF] to toggle the zone to by bypasses/un-bypassed.
    4. Press [OK] to save and exit, or press [MENU] to exit without saving.
    Repeat steps 1 to 4 to bypass or un-bypass additional zones.

  • Chime Mode

    Enter programming mode [PIN + MENU] then,
    1. Enter [MENU] + [3] + [0] + [3].
    A list of areas will display on the keypad.
    2. Use the up and down keys to the select the area that you want to program zones for chime mode, then press [OK]
    The keypad will display all zones that can be set to chime mode.
    3. Use the up and down keys to select the zone that you want to set for chime, then press [OK]. Alternatively, you can enter the zone number that you want to set for chime, then press [OK].
    4. Press [ON] or [OFF] to toggle the zone to be monitored when chime mode is turned on.
    5. Press [OK] to save and exit, or press [MENU] to exit without saving.

  • Resetting a smoke detector

    1. Enter [MENU] + [3} + [0] + [5]
    A list of different areas will display on the keypad.
    2. Use the up and down keys to select the are you want to reset the smoke detects, then press [OK] to select, Alternatively, you can enter the area number, then press [OK]
    3. The keypad will automatically return to the menu when all smoke detectors in the area have been reset.